InitRech 2015/2016, sujet 14 : Différence entre versions

De Wiki de Projets IMA
Ligne 5 : Ligne 5 :
 
===SUMMARY===
 
===SUMMARY===
  
The article argue mainly about the interest of computer simulator in the interventional radiology.It is not an easy task to realize or to create a real time simulator.The main problem is to find solution when a blending occurs between 2 vessels(eg.:internal hemorrhage,...)
+
The article argues mainly about the interest of computer simulator in the interventional radiology.It is not an easy task to realize or to create a real-time simulator.The main problem is to find solution when a blending occurs between 2 vessels(eg.:internal hemorrhage,aneurysm...)
This requires a blood vessel surface;some engineers focused their interest on the real time simulation in term of vizualisation by proposing an algorithm model.
+
Some engineers focused their interest on the real-time simulation in terms of vizualisation by proposing an algorithm model.
This algorithm model embraces 5 points.
+
The algorithm model embraces 5 points.The first one consist into representing a surface by a mathematical formulation.With this formulation,they have been able to do a sum of spheres.
the first one consist into representing a surface by a mathematical formulation.With this formulation we will able to do a sum of sphères.
+
After the conceptual phase,they deal with an other point:minimization of the energy in order to avoid collision.As we know,every body's cell needs energy to be functionnal.A surface can be describe as a plan,which means that it is defined by many points(cells).The Lennard-Jones energy validates the model.
after the conceptual phase,they deal with an other point:minimization of the energy in order to avoid collision.As we know,every body cell needs energy to be functionnal.A surface can be describe as a plan which means that it is defined by many points(cells).The Lennard Jones energy validate the model.
+
They also tried to subdivise the blob..........
They also tried to subdivise the blob
 
  
  
they consider an optimization subdivision.the subdivision can occasion a high number of blob sections.Which is not reliable because may lead to a collision.
+
They consider an optimization subdivision.The subdivision can occasion a high number of blob sections.Which is not reliable,because may lead to a collision.
They use the model for simulation by taking due account the Equipment used in medical field.
+
They use the model for simulation by taking due account the equipment used in medical field.
  
They made experiences by using 5 patient data.the data involve the internal carotid artery.they ysed the Cauchy algorithm for its efficiency and  Lennard-Jones energy(described above).
+
They also made experiences by using 5 patient data.Data involve the internal carotid artery.The Cauchy algorithm has been used for its efficiency and  Lennard-Jones energy(described above).
 
However,some geometric errors occur and had to be fixed by Taubin's approximate distance.But 2 parameters had to be taken into account such as the distance between 2 blobs and the number of subdivision.
 
However,some geometric errors occur and had to be fixed by Taubin's approximate distance.But 2 parameters had to be taken into account such as the distance between 2 blobs and the number of subdivision.
the other point to tackle was to quantify the the efficiency of the model and computation time3.modelizing one patient take an half hour.the goal was to comùpare the number of blobs and the number of triangle on the isosurface.in one hand the test was conclusive but in other hand the model is not able to simulate the vessel due to discontinuities.
 
in conclusion, the model has been integrated in the simulation software and tested on a pecific patient,in the future a global perspective within sight is to use make simulation with image data.
 
  
 +
The other point to tackle was to quantify the efficiency of the model and computation time3.modelizing one patient take an half hour.The purpose was to compare the number of blobs and the number of triangle on the isosurface.In one hand,the test was conclusive but in other hand,the model was not able to simulate the vessel due to discontinuities.
 +
In conclusion, the model has been integrated in the simulation software and tested on a specific patient.In the future a global perspective within sight is to use make simulation with image data.
  
results
 
  
  
 
===MAIN CONTRIBUTION===
 
===MAIN CONTRIBUTION===
 +
First of all, a model of the vessel have been proposed.the main contribution is that they had been able to simulate differents shapes and states of vessels in real time.Secondly,this is very important for treating aneurysm (which is an abnormal swelling of vessels)in order to prevent the rupture.
  
to be continued.....
 
  
  
Ligne 33 : Ligne 31 :
  
 
===SOME APPLICATIONS===
 
===SOME APPLICATIONS===
 +
 
There are a lot of applications especially in the medical domain.Those kind of researches will help to resolve important issues in human arteries in vascular disease characterization and assessment.The algorithm model combined with the 3-D modeling will provide a suitable modelisation of blood vessels.
 
There are a lot of applications especially in the medical domain.Those kind of researches will help to resolve important issues in human arteries in vascular disease characterization and assessment.The algorithm model combined with the 3-D modeling will provide a suitable modelisation of blood vessels.
With recent advances in medical imaging,it will be possible to treat and anlyse many diseases with anatomic data specific to the patient.
+
With recent advances in medical imaging,it will be possible to treat and analyse many diseases with anatomic data specific to the patient.
  
As an example,during the intervention,it is better for a doctor to visualize exactly what is happening in real time.It is very interesting for internal hemorrhage for example, or in case of cerebrovascular accident,or liver treatment,goitre and thyroid dysfunction..
+
As an example,during the intervention,it is better for a doctor to visualize exactly what is happening in real time.For example,in case of internal hemorrhage,cerebrovascular accident,or liver treatment,goitre and thyroid dysfunction...
 
With technological advance,precision is guaranted and a reduction of chirurgical accidents.
 
With technological advance,precision is guaranted and a reduction of chirurgical accidents.
Perhaps,it is also conceivable the treatment of obesity;a disease mainly caused by a high level of LDL(Bad Cholesterol,in this context,LDL is responsible of atherogenesis).this modelisation will help to move around the vessel and localize the lesion area.
+
Perhaps,it is also conceivable the treatment of obesity;a disease mainly caused by a high level of LDL(Bad Cholesterol,in this context,LDL is responsible of atherogenesis).This modelisation will help to move around the vessel and localize the lesion area.

Version du 17 juin 2016 à 13:42

BROUILLON TO BE CONTINUED....


SUMMARY

The article argues mainly about the interest of computer simulator in the interventional radiology.It is not an easy task to realize or to create a real-time simulator.The main problem is to find solution when a blending occurs between 2 vessels(eg.:internal hemorrhage,aneurysm...) Some engineers focused their interest on the real-time simulation in terms of vizualisation by proposing an algorithm model. The algorithm model embraces 5 points.The first one consist into representing a surface by a mathematical formulation.With this formulation,they have been able to do a sum of spheres. After the conceptual phase,they deal with an other point:minimization of the energy in order to avoid collision.As we know,every body's cell needs energy to be functionnal.A surface can be describe as a plan,which means that it is defined by many points(cells).The Lennard-Jones energy validates the model. They also tried to subdivise the blob..........


They consider an optimization subdivision.The subdivision can occasion a high number of blob sections.Which is not reliable,because may lead to a collision. They use the model for simulation by taking due account the equipment used in medical field.

They also made experiences by using 5 patient data.Data involve the internal carotid artery.The Cauchy algorithm has been used for its efficiency and Lennard-Jones energy(described above). However,some geometric errors occur and had to be fixed by Taubin's approximate distance.But 2 parameters had to be taken into account such as the distance between 2 blobs and the number of subdivision.

The other point to tackle was to quantify the efficiency of the model and computation time3.modelizing one patient take an half hour.The purpose was to compare the number of blobs and the number of triangle on the isosurface.In one hand,the test was conclusive but in other hand,the model was not able to simulate the vessel due to discontinuities. In conclusion, the model has been integrated in the simulation software and tested on a specific patient.In the future a global perspective within sight is to use make simulation with image data.


MAIN CONTRIBUTION

First of all, a model of the vessel have been proposed.the main contribution is that they had been able to simulate differents shapes and states of vessels in real time.Secondly,this is very important for treating aneurysm (which is an abnormal swelling of vessels)in order to prevent the rupture.



SOME APPLICATIONS

There are a lot of applications especially in the medical domain.Those kind of researches will help to resolve important issues in human arteries in vascular disease characterization and assessment.The algorithm model combined with the 3-D modeling will provide a suitable modelisation of blood vessels. With recent advances in medical imaging,it will be possible to treat and analyse many diseases with anatomic data specific to the patient.

As an example,during the intervention,it is better for a doctor to visualize exactly what is happening in real time.For example,in case of internal hemorrhage,cerebrovascular accident,or liver treatment,goitre and thyroid dysfunction... With technological advance,precision is guaranted and a reduction of chirurgical accidents. Perhaps,it is also conceivable the treatment of obesity;a disease mainly caused by a high level of LDL(Bad Cholesterol,in this context,LDL is responsible of atherogenesis).This modelisation will help to move around the vessel and localize the lesion area.